Impulse Generator Manufacturer Exporter to Angola


Impulse Generators operates under a control system, which charges the impulse generator by the  charging unit. Charging time and charging voltage can be selected. Once the selected charging voltage has been reached, a trigger pulse initiates the firing of the lowest spark-gap of the impulse generator. When all the spark-gaps fired all the stages are connected in series thus multiplying the charging voltage. The impulse voltage divider reduces he impulse voltage to a value that the measuring and recording instruments require.

Features:

  • Charging Rectifier
  • Impulse generator to generate lightning impulses
  • Control and measuring system.
  • Divider.
  • Shunt
  • Chopping Gap / Multiple Chopping Gap.
  • Resistor set to generate switching impulses 250/2500.
  • Overshoot Compensation.
  • Measuring system.
  • Set to Generate impulse currents


For further details or requirements, email us at info@re-india.com

Sphere Gaps Manufacturer Exporter to Ghana


Sphere Gap is provided with Motorised arrangement to adjust the gap. The lower sphere gap shall Motorised and shall move upwards and downwards for the adjustment of gap. The upper sphere shall be hang shall be roof of the test lab with in insulator and current limiting resistance shall be provided.

Available upto 500mm sphere supplied upto 300mm sphere.
Digital distance measurement.

For further details or requirements, email us at info@re-india.com

Cable Fault Burning Unit Manufacturer Exporter to Mali


Cable Fault Burning Unit converts high resistance faults to short circuit faults. Available for HV/LV cables. For manufactures use only. Helps save the damaged part.

Features:
Helps utilize the TDR.
LV Fault Burner upto 30kVA.
HV Fault Burner Upto 70kVA.

For further details or requirements, email us at info@re-india.com

Tracking Resistance Erosion Test Equipment Manufacturer Exporter to Libya


Tracking Resistance Erosion Test Equipment is used for checking the relative behavior of solid electrical insulating material with regard to their susceptibility to surface tracking when exposed under electric stresses, to water and contaminants, from the surroundings.

The grading of materials arrived at by checking the tracking index may possibly differ from that obtained by utilizing other checking methods for the measurements of the tracking index.

The results obtained by checking tracking index are not used directly for evaluation of safe creepage distances while designing any electrical apparatus.

With this apparatus drops of an electrolyte are dropped at defined time interval to the surface of insulating materials between two electrodes to which a voltage is applied.

The number of drops at which break down occurs across the surface is the function of voltage

The numerical values of the voltage corresponding to the asymptotes defines the tracking resistance.The value of voltage corresponding to number of drops is taken as the comparative index. (This test should be done as fast as possible)

The number of drops to cause tracking at value of predetermined test voltage 10% below the number of drops value is indicated as the degree to which the reported comparative tracking.

For further details or requirements, email us at info@re-india.com