AC High Voltage Low Capacity Test Sets for Testing Insulators



AC High Voltage Low capacity testers are  specially designed for testing Insulators, CT’s PT’s, Low dielectric capacitive electrical equipment, transformers etc. as per National and International  Standards.  During  manufacturing each unit is tested at multiple stages, thus ensuring consistency and best  quality. These instruments are air cooled, oil cooled or air & oil cooled combined as per design. The units have been manufactured up to 800kV and up to 200kVA.The units have type of tests such as dry withstand, wet withstand, breakdown voltage in air/oil, oil insulation, and pollution Test.

AC High Voltage Low Capacity Test Set
Sr. No.
Parameters
Description
1
I/p Voltage 
220/230V or 380/400V, 50 or 60HZ AC supply
2
O/p Voltage
Up 800KV and 250mA
3
Capacity
Up  to 200KVA
4
Timer
0-9999 Sec./min. Digital
5
Control
Type 1- The unit can be manual/motorized control for voltage variation and push button controlled for HT actuation.
Type  2- The unit can be complete with on board digitized panel with or without computer connectivity.
Type  3- The unit can be PLC based complete with computer, HMI memory, printer etc. for operation.
6
Metering
Voltmeter : One Digital type connected on HT side to indicate the output voltage
Scale :  0-800 kV AC.
Ammeter : One Digital type ammeter Connected on earth side to indicate the leakage Current on sample under test.
Scale :  0-500mA
Applicable only for type -1
For type -2 and type 3 metering is self contained
7
Protection 
Tripping   -  A fast acting DC relay will isolate the circuit when the current exceeds pre-set level.
Overload  - This is used as a  secondary protection  in case the input loads exceeds the preset value
Overvoltage -  This is used as a  secondary protection  in case the output voltage exceeds the preset value
8
Interlocking
Zero Start Interlock  -  The unit will have zero start interlocking to avoid the transients on HV transformer and provision for  cage door interlocking shall also be provided.
Earth interlock- It ensures that HV will not actutae untill good earthing is not provided.
9
Termination
The HT output on suitable HT insulator and other point at earth potential will be brought out on suitable insulator
10
Control Panel
The control panel is designed for five unique purposes.
1 -Control
2- Measure
3- Protect (Active and Passive)
4- Tripping
5 -Annunciate   
11
HV Transformer

The transformers are designed and manufactured as per IS /IEC guidelines. Single /  Multiple stage stepup transformers are utilized  for achiving the desired voltage. The units are designed and manufactured using the  preeminent material from India and Abroad. The coils are vacuum impregnated and insulated with High Quality EHV Grade transformer oil as per relevant IS and IEC Standard.



For further details or requirements, Email us